AD7991 LINUX DRIVER
If that input is not used as the reference voltage, it uses the supply voltage as the reference voltage. This adds significant extra complexity, however, as basic bus control can be accomplished with the open, ioctl, read, and write commands. Examples shown on this page were developed based on a Texas Instruments BeagleBoard and some changes will be required depending on the system being utilized. By default i2c2 was properly configured and enabled. A call to open must be used rather than fopen so that writes to the bus are not buffered. To enable i2c2 specifically during that process, enable the setting during the “make menuconfig” step.
Uploader: | Zulutaur |
Date Added: | 7 November 2012 |
File Size: | 69.95 Mb |
Operating Systems: | Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X |
Downloads: | 32372 |
Price: | Free* [*Free Regsitration Required] |
It is important to note that the linuxx of enabling i2c2 varies depending on your kernel and applied patches. For devices with more than one configuration register, the address of the register should be written first, followed by the data to be placed there.
By default i2c2 was properly configured and enabled. Open returns a new file descriptor a non-negative integer which can then be used to configure the bus. This page was last edited on 8 Octoberat See the glib api for more details.
See page 21 of the datasheet for more details.
Linux source code: ad identifier (v) – Bootlin
The AD contains only one configuration register, and as such, does not require a internal register selection address to be sent to the device. Although a few manufacturers actually say which method they use to describe the address, the vast majority do not, and the user may have to resort to testing via trial and error. Some devices require an internal address to be sent prior to the data to specify the register on the external device to access.
In order to compile the code and create a binary that can be run on the embedded system, you will need a cross compiler e. Because the AD is bit device, its outputs ranges linearly from 0 to as the voltage ranges from 0 to the reference voltage.
Read requires a file handle, a buffer to store the data, and a number of bytes to read. To enable i2c2 specifically during that process, enable the setting during the “make menuconfig” step. For simple usage, calling lijux function as ad7919 will work. This adds significant extra complexity, however, as basic bus control can be accomplished with the open, ioctl, read, and write commands.
After successfully acquiring bus access, you must initiate communication with whatever peripheral you are attempting to utilize. For example, with the BeagleBoard:. The power on default configuration uses all 4 channels as inputs, so in this case no further configuration is necessary.
However, by limux bus 2 is disabled due to a lack of pull-up resistors on the board, so external pull-ups to 1. Rather than waste the empty bits, two of them are also used to signal the channel data being sent. The AD samples a 12 bit value, which is read back as two eight bit values.
Views Read View source View history. If that input is not used as the reference voltage, it uses the supply voltage as the reference voltage.
This is useful for checking what devices are functioning properly. As bus llnux is by far the easiest to connect to linyx to its presence on the 0. The AD has four inputs as well as the ability to use one of the input pins as a reference voltage the other inputs are measured against. Others will provide it as an eight bit number and assume you will set the last bit accordingly. Privacy policy About eLinux.
iio: ad799x: Fix buffered capture for ad7991/ad7995/ad7999 [Linux 4.4.22]
The AD used in this example is the AD, which has an address reported by the datasheet as Adding the user to a group which has permissions to access the file will alleviate this problem, as will adjusting linx file permissions to enable user access. To use this properly, zero pad the address on the left and store it as 0b Navigation menu Personal tools Log in Request account. The bit is set to 0 for writes and 1 for reads. Retrieved from ” https: